人L-型电压依赖钙离子通道α1C亚基(CACNa1C)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK0012
规格: 价格:
48T ¥2240.00
96T ¥3200.00

Overview

Product name: Human CACNa1C(Calcium Channel, Voltage Dependent, L-Type, Alpha 1C Subunit) ELISA Kit
Reactivity: Human
Alternative Names: CACH2; CACN2; CACNL1A1; CCHL1A1; CaV1.2; TS; Voltage-gated calcium channel subunit alpha Cav1.2; Calcium channel, L type, alpha-1 polypeptide, isoform 1, cardiac muscle
Assay Type: Sandwich
Sensitivity: 0.12 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample type: Tissue homogenates and other biological fluids.
Assay length: 3.5h
Research Area: Signal transduction;
Uniprot ID: Q13936
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CACNa1C. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CACNa1C. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CACNa1C, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CACNa1C in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
20.00 2.169 2.082
10.00 1.593 1.506
5.00 1.316 1.229
2.50 0.841 0.754
1.25 0.563 0.476
0.63 0.325 0.238
0.32 0.235 0.148
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CACNa1C and the recovery rates were calculated by comparing the measured value to the expected amount of CACNa1C in samples.
Matrix Recovery range Average
serum(n=5) 84-97% 90%
EDTA plasma(n=5) 95-107% 101%
Heparin plasma(n=5) 77-95% 86%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CACNa1C and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 87-103% 97-105% 79-90%
EDTA plasma(n=5) 89-101% 85-96% 95-104% 82-90%
Heparin plasma(n=5) 85-93% 87-96% 97-105% 95-102%