99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

猪血小板因子4(PF4)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK10699
规格: 价格:
48T ¥2240.00
96T ¥3200.00

Overview 文献(1)

Product name: Pig PF4(Platelet Factor 4) ELISA Kit
Reactivity: Pig
Alternative Names: CXCL4; SCYB4; Chemokine C-X-C-Motif Ligand 4; Oncostatin-A; Iroplact
Assay Type: Sandwich
Sensitivity: 6.5 ng/mL
Standard: 1000 ng/mL
Detection Range: 15.63-1000 ng/mL
Sample type: Plasma.
Assay length: 3.5h
Research Area: Cytokine;Hematology;
Uniprot ID: P30034
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Pig PF4. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Pig PF4. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Pig PF4, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Pig PF4 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
1000.00 2.179 2.084
500.00 1.703 1.608
250.00 1.174 1.079
125.00 0.852 0.757
62.50 0.563 0.468
31.25 0.357 0.262
15.63 0.156 0.061
0.00 0.095 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PF4 and the recovery rates were calculated by comparing the measured value to the expected amount of PF4 in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 87-93% 90%
Heparin plasma(n=5) 84-106% 100%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PF4 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 90-99% 95-106% 87-101% 82-97%
EDTA plasma(n=5) 91-99% 88-97% 88-104% 97-108%
Heparin plasma(n=5) 95-103% 87-98% 85-92% 79-96%
关闭

在线咨询

Online consultation

  • 在线咨询
  • 技术支持

关注微信公众号

微信扫一扫立即咨询

微信扫一扫立即咨询

关闭
Baidu
sogou