Product name: Human HSPA1A(Heat Shock 70kDa Protein 1A) ELISA Kit
Reactivity: Human
Alternative Names: HSP70-1; HSP-A1A; HSPA1; HSP70-2; HSX70
Assay Type: Sandwich
Sensitivity: 0.6 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay length: 3.5h
Research Area: Signal transduction;Tumor immunity;Infection immunity;Developmental science;
Uniprot ID: P0DMV8
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human HSPA1A. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human HSPA1A. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human HSPA1A, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human HSPA1A in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
100.00 1.941 1.848
50.00 1.562 1.469
25.00 1.128 1.035
12.50 0.901 0.808
6.25 0.427 0.334
3.13 0.361 0.268
1.57 0.199 0.106
0.00 0.093 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant HSPA1A and the recovery rates were calculated by comparing the measured value to the expected amount of HSPA1A in samples.
Matrix Recovery range Average
serum(n=5) 84-97% 91%
EDTA plasma(n=5) 89-105% 97%
Heparin plasma(n=5) 78-90% 84%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HSPA1A and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-96% 91-101% 87-98% 89-103%
EDTA plasma(n=5) 78-92% 79-93% 94-106% 83-97%
Heparin plasma(n=5) 80-92% 86-102% 87-103% 85-101%