99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

人δ-促睡眠肽(dSIP)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK1946
规格: 价格:
48T ¥1960.00
96T ¥2800.00

Overview 文献(1)

Product name: Human dSIP(Delta-Sleep Inducing Peptide) ELISA Kit
Reactivity: Human
Alternative Names: DSIPI; TSC22D3; DIP; GILZ; TSC-22R; hDIP; TSC22 Domain Family Protein 3; Glucocorticoid-Induced Leucine Zipper; Delta Sleep Inducing Peptide,Immunoreactor
Assay Type: Competitive Inhibition
Sensitivity: 7.49 pg/mL
Standard: 1500 pg/mL
Detection Range: 23.44-1500 pg/mL
Sample type: Serum, plasma, tissue homogenates and other biological fluids
Assay length: 2h
Research Area: Reproductive science;Neuro science;Hormone metabolism;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human dSIP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human dSIP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human dSIP in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
1500.00 0.221
750.00 0.387
375.00 0.692
187.50 0.933
93.75 1.253
46.88 1.587
23.44 1.871
0.00 2.265

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant dSIP and the recovery rates were calculated by comparing the measured value to the expected amount of dSIP in samples.
Matrix Recovery range Average
serum(n=5) 78-93% 85%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 90-103% 96%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of dSIP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 97-103% 82-90% 92-101%
EDTA plasma(n=5) 95-102% 97-105% 92-101% 85-92%
Heparin plasma(n=5) 92-104% 82-96% 95-102% 87-98%