99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

人C4结合蛋白β(C4BPb)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK2112
规格: 价格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human C4BPb(C4 Binding Protein Beta) ELISA Kit
Reactivity: Human
Alternative Names: C4BP-B; C4-BP; Complement Component 4 Binding Protein
Assay Type: Sandwich
Sensitivity: 13.8 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample type: Serum, plasma and other biological fluids
Assay length: 3.5h
Research Area: Infection immunity;Immune molecule;Developmental science;
Uniprot ID: P20851
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human C4BPb. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human C4BPb. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human C4BPb, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human C4BPb in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
2000.00 2.045 1.959
1000.00 1.577 1.491
500.00 1.067 0.981
250.00 0.872 0.786
125.00 0.572 0.486
62.50 0.331 0.245
31.25 0.208 0.122
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant C4BPb and the recovery rates were calculated by comparing the measured value to the expected amount of C4BPb in samples.
Matrix Recovery range Average
serum(n=5) 85-97% 91%
EDTA plasma(n=5) 80-92% 86%
Heparin plasma(n=5) 92-107% 99%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of C4BPb and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 82-96% 85-98% 92-103% 81-95%
EDTA plasma(n=5) 83-97% 82-96% 86-98% 93-101%
Heparin plasma(n=5) 87-96% 86-95% 92-103% 81-90%