人ATP结合盒转运蛋白A3(ABCA3)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK3587
规格: 价格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human ABCA3(ATP Binding Cassette Transporter A3) ELISA Kit
Reactivity: Human
Alternative Names: ABC-A3; ABC-C; ABC3; ABC-C transporter
Assay Type: Sandwich
Sensitivity: 32 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample type: Tissue homogenates and other biological fluids.
Assay length: 3.5h
Research Area: Signal transduction;
Uniprot ID: Q99758
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human ABCA3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human ABCA3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human ABCA3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human ABCA3 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
5000.00 2.075 1.986
2500.00 1.647 1.558
1250.00 1.213 1.124
625.00 0.797 0.708
312.50 0.457 0.368
156.25 0.335 0.246
78.13 0.252 0.163
0.00 0.089 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant ABCA3 and the recovery rates were calculated by comparing the measured value to the expected amount of ABCA3 in samples.
Matrix Recovery range Average
serum(n=5) 81-97% 89%
EDTA plasma(n=5) 84-97% 90%
Heparin plasma(n=5) 82-94% 88%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ABCA3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 92-106% 92-101% 80-95% 87-96%
EDTA plasma(n=5) 85-92% 79-96% 89-100% 85-96%
Heparin plasma(n=5) 86-93% 93-101% 86-97% 90-101%