人黑素瘤缺乏因子2(AIM2)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK4291
规格: 价格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human AIM2(Absent In Melanoma 2) ELISA Kit
Reactivity: Human
Alternative Names: PYHIN4; Interferon-inducible protein AIM2
Assay Type: Sandwich
Sensitivity: 0.063 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample type: serum, plasma, tissue homogenates, cell lysates and other biological fluids
Assay length: 3.5h
Research Area: Tumor immunity;
Uniprot ID: O14862
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human AIM2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human AIM2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human AIM2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human AIM2 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
10.00 2.131 2.048
5.00 1.563 1.480
2.50 1.182 1.099
1.25 0.861 0.778
0.63 0.509 0.426
0.32 0.329 0.246
0.16 0.168 0.085
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant AIM2 and the recovery rates were calculated by comparing the measured value to the expected amount of AIM2 in samples.
Matrix Recovery range Average
serum(n=5) 80-95% 87%
EDTA plasma(n=5) 78-96% 87%
Heparin plasma(n=5) 78-92% 85%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of AIM2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-96% 87-101% 89-97% 85-94%
EDTA plasma(n=5) 86-99% 93-107% 85-94% 87-101%
Heparin plasma(n=5) 82-96% 85-98% 95-104% 82-96%