99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

人胆囊收缩素25(CCK25)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK5611
规格: 价格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human CCK25(Cholecystokinin 25) ELISA Kit
Reactivity: Human
Alternative Names: CCK25
Assay Type: Competitive Inhibition
Sensitivity: 4.63 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay length: 2h
Research Area: Tumor immunity;Endocrinology;Neuro science;Hepatology;Hormone metabolism;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human CCK25. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CCK25. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CCK25 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
1000.00 0.221
500.00 0.387
250.00 0.655
125.00 0.856
62.50 1.225
31.25 1.596
15.63 1.835
0.00 2.211

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CCK25 and the recovery rates were calculated by comparing the measured value to the expected amount of CCK25 in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 85-99% 92%
Heparin plasma(n=5) 78-92% 100%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CCK25 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 96-104% 97-105% 95-103%
EDTA plasma(n=5) 88-97% 86-92% 81-93% 89-105%
Heparin plasma(n=5) 98-107% 93-101% 97-103% 91-99%