99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

人CD200受体2(CD200R2)微量上样酶联免疫吸附检测试剂盒
一键复制产品信息
ELK6661MS
规格: 价格:
48T ¥2240.00
96T ¥3200.00

Overview

Product name: Human CD200R2(CD200 Receptor 2) Microsample ELISA Kit
Reactivity: Human
Alternative Names: CD200R1L; CD200RLa; HuCD200R2; Cell surface glycoprotein CD200 receptor 2; CD200 cell surface glycoprotein receptor-like a; Cell surface glycoprotein OX2 receptor 2
Assay Type: Sandwich
Sensitivity: 0.54 ng/mL
Standard: 100 ng/mL
Detection Range: 1.56-100 ng/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates and other biological fluids.
Assay Length: 3.5h
Research Area: CD & Adhesion molecule;
Uniprot ID: Q6Q8B3
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CD200R2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CD200R2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CD200R2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CD200R2 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
100.00 2.107 2.013
50.00 1.522 1.428
25.00 1.057 0.963
12.50 0.780 0.686
6.25 0.598 0.504
3.13 0.380 0.286
1.56 0.229 0.135
0.00 0.094 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CD200R2 and the recovery rates were calculated by comparing the measured value to the expected amount of CD200R2 in samples.
Matrix Recovery range Average
serum(n=5) 82-102% 92%
EDTA plasma(n=5) 89-124% 107%
Heparin plasma(n=5) 87-97% 92%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CD200R2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 82-120% 91-116% 84-93% 86-103%
EDTA plasma(n=5) 81-101% 85-96% 83-97% 87-117%
Heparin plasma(n=5) 80-117% 91-113% 92-105% 89-102%

产品成分表

关闭

在线咨询

Online consultation

  • 在线咨询
  • 技术支持

关注微信公众号

微信扫一扫立即咨询

微信扫一扫立即咨询

关闭
Baidu
sogou