99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

人CD8b分子(CD8b)微量上样酶联免疫吸附检测试剂盒
一键复制产品信息
ELK7411MS
规格: 价格:
48T ¥2240.00
96T ¥3200.00

Overview

Product name: Human CD8b(Cluster Of Differentiation 8b) Microsample ELISA Kit
Reactivity: Human
Alternative Names: CD8B1; CD8 Antigen,Beta Polypeptide 1; T-cell surface glycoprotein CD8 beta chain
Assay Type: Sandwich
Sensitivity: 0.56 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: Tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
Assay Length: 3.5h
Research Area: CD & Adhesion molecule;
Uniprot ID: P10966
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CD8b. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CD8b. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CD8b, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CD8b in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
100.00 2.226 2.146
50.00 1.700 1.620
25.00 1.122 1.042
12.50 0.843 0.763
6.25 0.640 0.560
3.13 0.315 0.235
1.56 0.217 0.137
0.00 0.080 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CD8b and the recovery rates were calculated by comparing the measured value to the expected amount of CD8b in samples.
Matrix Recovery range Average
serum(n=5) 87-106% 97%
EDTA plasma(n=5) 84-108% 96%
Heparin plasma(n=5) 84-107% 96%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CD8b and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-110% 86-115% 87-95% 85-94%
EDTA plasma(n=5) 93-117% 80-85% 83-116% 89-116%
Heparin plasma(n=5) 87-117% 95-116% 85-113% 90-99%

产品成分表

关闭

在线咨询

Online consultation

  • 在线咨询
  • 技术支持

关注微信公众号

微信扫一扫立即咨询

微信扫一扫立即咨询

关闭
Baidu
sogou