Overview

Product name: Mouse CLEC10A(C-Type Lectin Domain Family 10, Member A) Microsample ELISA Kit
Reactivity: Mouse
Alternative Names: CD301; CLEC10-A; CLECSF13; CLECSF14; Macrophage Lectin 2(Calcium Dependent); C-type lectin superfamily member 14; Macrophage lectin 2
Assay Type: Sandwich
Sensitivity: 0.063 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;CD & Adhesion molecule;Tumor immunity;Infection immunity;
Uniprot ID: P49300
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse CLEC10A. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse CLEC10A. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse CLEC10A, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse CLEC10A in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
10.00 2.412 2.323
5.00 1.545 1.456
2.50 1.149 1.060
1.25 0.951 0.862
0.63 0.517 0.428
0.31 0.306 0.217
0.16 0.179 0.090
0.00 0.089 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CLEC10A and the recovery rates were calculated by comparing the measured value to the expected amount of CLEC10A in samples.
Matrix Recovery range Average
serum(n=5) 83-101% 92%
EDTA plasma(n=5) 89-107% 98%
Heparin plasma(n=5) 83-102% 93%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CLEC10A and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-118% 84-98% 90-107% 92-103%
EDTA plasma(n=5) 92-119% 85-91% 89-105% 87-113%
Heparin plasma(n=5) 82-99% 94-104% 87-103% 83-110%