99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

小鼠C-型钠尿肽(CNP)微量上样酶联免疫吸附检测试剂盒
一键复制产品信息
ELK7872MS
规格: 价格:
48T ¥2240.00
96T ¥3200.00

Overview

Product name: Mouse CNP(C-Type Natriuretic Peptide) Microsample ELISA Kit
Reactivity: Mouse
Alternative Names: ANFC; C type natriuretic peptide precursor ; CNP-53 ; CNP2 ; Natriuretic peptide C ; Natriuretic peptide precursor C ; NPPC
Assay Type: Sandwich
Sensitivity: 0.95 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Cardiovascular biology;Hormone metabolism;
Uniprot ID: Q61839
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse CNP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse CNP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse CNP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse CNP in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
2000.00 2.167 2.077
1000.00 1.684 1.594
500.00 1.158 1.068
250.00 0.859 0.769
125.00 0.479 0.389
62.50 0.324 0.234
31.25 0.156 0.066
0.00 0.090 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CNP and the recovery rates were calculated by comparing the measured value to the expected amount of CNP in samples.
Matrix Recovery range Average
serum(n=5) 84-92% 88%
EDTA plasma(n=5) 83-116% 100%
Heparin plasma(n=5) 90-112% 101%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CNP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-98% 81-118% 87-95% 90-110%
EDTA plasma(n=5) 91-98% 84-102% 81-100% 80-112%
Heparin plasma(n=5) 82-105% 83-100% 93-110% 92-116%