99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

小鼠生长激素(GH)微量上样酶联免疫吸附检测试剂盒
一键复制产品信息
ELK7884MS
规格: 价格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Mouse GH(Growth Hormone) Microsample ELISA Kit
Reactivity: Mouse
Alternative Names: GH1; GH-N; GHN; hGH-N; Somatotropin; Hygetropin; Jintropin; Kigtropin; Pituitary Growth Hormone; Growth Hormone, Normal
Assay Type: Sandwich
Sensitivity: 33 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Endocrinology;Neuro science;Hormone metabolism;
Uniprot ID: P06880
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse GH. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse GH. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse GH, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse GH in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
5000.00 2.022 1.935
2500.00 1.503 1.416
1250.00 1.204 1.117
625.00 0.814 0.727
312.50 0.452 0.365
156.25 0.414 0.327
78.13 0.253 0.166
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GH and the recovery rates were calculated by comparing the measured value to the expected amount of GH in samples.
Matrix Recovery range Average
serum(n=5) 94-110% 102%
EDTA plasma(n=5) 88-101% 95%
Heparin plasma(n=5) 90-104% 97%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GH and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 90-97% 86-116% 89-104% 83-112%
EDTA plasma(n=5) 85-111% 83-119% 86-117% 90-99%
Heparin plasma(n=5) 84-110% 92-104% 89-100% 80-103%