99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

雄甾酮(ADT)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK7926
规格: 价格:
48T ¥2240.00
96T ¥3200.00

Overview

Product name: ADT(Androsterone) ELISA Kit
Reactivity: General
Alternative Names: 17-Ketosteroid; 17-KS; 3a-Hydroxy-17-Androstanone
Assay Type: Competitive Inhibition
Sensitivity: 147 pg/mL
Standard: 90000 pg/mL
Detection Range: 1406.25-90000 pg/mL
Sample type: serum, plasma and other biological fluids
Assay length: 2h
Research Area: Endocrinology;Reproductive science;Hormone metabolism;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with ADT. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to ADT. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of ADT in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
90000.00 0.211
45000.00 0.389
22500.00 0.577
11250.00 0.833
5625.00 1.119
2812.50 1.522
1406.25 1.789
0.00 2.132

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant ADT and the recovery rates were calculated by comparing the measured value to the expected amount of ADT in samples.
Matrix Recovery range Average
serum(n=5) 80-97% 88%
EDTA plasma(n=5) 78-92% 85%
Heparin plasma(n=5) 90-105% 92%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ADT and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-98% 92-105% 82-98% 89-97%
EDTA plasma(n=5) 93-102% 81-96% 93-106% 82-95%
Heparin plasma(n=5) 85-94% 79-96% 89-100% 85-96%
关闭

在线咨询

Online consultation

  • 在线咨询
  • 技术支持

关注微信公众号

微信扫一扫立即咨询

微信扫一扫立即咨询

关闭
Baidu
sogou