1,25-二羟基维生素D3(DHVD3)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK8091
规格: 价格:
48T ¥1680.00
96T ¥2400.00

Overview 文献(2)

Product name: DHVD3(1,25-Dihydroxyvitamin D3) ELISA Kit
Reactivity: General
Alternative Names: DH-VD3; Calcitriol; Rocaltrol; Calcijex; 1,25-(OH)2D3; 1,25-Dihydroxycholecalciferol; 1,25-Dihydroxy Vitamin D3
Assay Type: Competitive Inhibition
Sensitivity: 48.8 pg/mL
Standard: 10000 pg/mL
Detection Range: 156.25-10000 pg/mL
Sample type: serum, plasma and other biological fluids
Assay length: 2h
Research Area: Metabolic pathway;Bone metabolism;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with DHVD3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to DHVD3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of DHVD3 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
10000.00 0.189
5000.00 0.386
2500.00 0.596
1250.00 0.878
625.00 1.169
312.50 1.592
156.25 1.796
0.00 2.112

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant DHVD3 and the recovery rates were calculated by comparing the measured value to the expected amount of DHVD3 in samples.
Matrix Recovery range Average
serum(n=5) 80-97% 88%
EDTA plasma(n=5) 82-98% 90%
Heparin plasma(n=5) 82-94% 90%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of DHVD3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 82-94% 85-96% 82-96% 95-102%
EDTA plasma(n=5) 87-98% 92-105% 83-92% 89-98%
Heparin plasma(n=5) 81-94% 81-96% 93-106% 82-95%