99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

人杀菌肽LL-37(LL-37)微量上样酶联免疫吸附检测试剂盒
一键复制产品信息
ELK8189MS
规格: 价格:
48T ¥2240.00
96T ¥3200.00

Overview

Product name: Human LL-37(Antibacterial Protein LL-37) Microsample ELISA Kit
Reactivity: Human
Alternative Names: CAP18; FALL39; HSD26; LL37; 18 kDa Cationic Antimicrobial Protein; Antibacterial protein FALL-39; FALL-39 peptide antibiotic; CAMP; Cathelicidin Antimicrobial Peptide
Assay Type: Sandwich
Sensitivity: 0.28 ng/mL
Standard: 50 ng/mL
Detection Range: 0.79-50 ng/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Infection immunity;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human LL-37. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human LL-37. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human LL-37, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human LL-37 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
50.00 2.040 1.957
25.00 1.561 1.478
12.50 1.015 0.932
6.25 0.875 0.792
3.13 0.517 0.434
1.56 0.337 0.254
0.78 0.226 0.143
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant LL-37 and the recovery rates were calculated by comparing the measured value to the expected amount of LL-37 in samples.
Matrix Recovery range Average
serum(n=5) 89-109% 99%
EDTA plasma(n=5) 94-113% 104%
Heparin plasma(n=5) 93-113% 103%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of LL-37 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-110% 86-94% 81-86% 90-98%
EDTA plasma(n=5) 84-115% 89-113% 93-104% 84-115%
Heparin plasma(n=5) 92-105% 85-95% 89-103% 88-112%

产品成分表

关闭

在线咨询

Online consultation

  • 在线咨询
  • 技术支持

关注微信公众号

微信扫一扫立即咨询

微信扫一扫立即咨询

关闭
Baidu
sogou