99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

小鼠线粒体开放阅读框12S rRNA-C(MOTS-c)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK8232
规格: 价格:
48T ¥2240.00
96T ¥3200.00

Overview

Product name: Mouse MOTS-c(Mitochondrial Open Reading Frame Of The 12S rRNA-c) ELISA Kit
Reactivity: Mouse
Alternative Names: MOTS-c
Assay Type: Competitive Inhibition
Sensitivity: 0.87 ng/mL
Standard: 200 ng/mL
Detection Range: 3.13-200 ng/mL
Sample type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay length: 2h
Research Area: Developmental science;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Mouse MOTS-c. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse MOTS-c. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse MOTS-c in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
200.00 0.211
100.00 0.467
50.00 0.675
25.00 0.967
12.50 1.157
6.25 1.565
3.13 1.861
0.00 2.132

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MOTS-c and the recovery rates were calculated by comparing the measured value to the expected amount of MOTS-c in samples.
Matrix Recovery range Average
serum(n=5) 84-106% 100%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 87-93% 89%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MOTS-c and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-102% 86-92% 95-103% 98-106%
EDTA plasma(n=5) 85-94% 87-96% 82-95% 81-93%
Heparin plasma(n=5) 87-94% 83-101% 86-99% 93-101%