99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

大鼠前心钠肽(Pro-ANP)微量上样酶联免疫吸附检测试剂盒
一键复制产品信息
ELK8360MS
规格: 价格:
48T ¥2240.00
96T ¥3200.00

Overview

Product name: Rat Pro-ANP(Pro Atrial Natriuretic Peptide) Microsample ELISA Kit
Reactivity: Rat
Alternative Names: Pro-ANP
Assay Type: Sandwich
Sensitivity: 15.2 pg/mL
Standard: 4000 pg/mL
Detection Range: 62.5-4000 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Endocrinology;Cardiovascular biology;
Uniprot ID: P01161
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat Pro-ANP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat Pro-ANP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat Pro-ANP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat Pro-ANP in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
4000.00 2.150 2.064
2000.00 1.661 1.575
1000.00 1.120 1.034
500.00 0.851 0.765
250.00 0.538 0.452
125.00 0.316 0.230
62.50 0.251 0.165
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant Pro-ANP and the recovery rates were calculated by comparing the measured value to the expected amount of Pro-ANP in samples.
Matrix Recovery range Average
serum(n=5) 90-102% 96%
EDTA plasma(n=5) 84-97% 91%
Heparin plasma(n=5) 93-120% 107%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Pro-ANP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 94-114% 95-105% 84-91% 81-97%
EDTA plasma(n=5) 81-102% 90-118% 83-120% 93-111%
Heparin plasma(n=5) 92-116% 92-104% 91-105% 93-107%

产品成分表

关闭

在线咨询

Online consultation

  • 在线咨询
  • 技术支持

关注微信公众号

微信扫一扫立即咨询

微信扫一扫立即咨询

关闭
Baidu
sogou