Product name: Mouse 4-HNE(4-Hydroxynonenal) Microsample ELISA Kit
Reactivity: Mouse
Alternative Names: 4-HNE, HNE, 4-hydroxy-2-nonenal, 6-Hydroxynonenal
Assay Type: Sandwich
Sensitivity: 1.1 ng/mL
Standard: 150 ng/mL
Detection Range: 2.35-150 ng/mL
Sample Type: Serum, plasma and other biological fluids.
Assay Length: 3.5h
Research Area: Signal transduction;Metabolic pathway;Infection immunity;Hormone metabolism;Dermatology;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse 4-HNE. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse 4-HNE. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse 4-HNE, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse 4-HNE in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
150.00 1.979 1.889
75.00 1.828 1.738
37.50 1.309 1.219
18.75 0.868 0.778
9.38 0.593 0.503
4.69 0.331 0.241
2.34 0.197 0.107
0.00 0.090 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant 4-HNE and the recovery rates were calculated by comparing the measured value to the expected amount of 4-HNE in samples.
Matrix Recovery range Average
serum(n=5) 85-101% 93%
EDTA plasma(n=5) 94-112% 103%
Heparin plasma(n=5) 90-107% 99%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of 4-HNE and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 81-102% 86-92% 94-101% 81-117%
EDTA plasma(n=5) 92-118% 81-93% 83-113% 88-95%
Heparin plasma(n=5) 84-112% 93-106% 91-101% 91-114%