99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

人结合蛋白2(TRAF2)微量上样酶联免疫吸附检测试剂盒
一键复制产品信息
ELK8544MS
规格: 价格:
48T ¥2240.00
96T ¥3200.00

Overview

Product name: Human TRAF2(TNF Receptor-Associated Factor 2) Microsample ELISA Kit
Reactivity: Human
Alternative Names: TRAF2; TRAP3; TNF receptor-associated factor 2; E3 ubiquitin-protein ligase TRAF2; Tumor necrosis factor type 2 receptor-associated protein 3
Assay Type: Sandwich
Sensitivity: 25 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity
Uniprot ID: Q12933
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TRAF2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human TRAF2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human TRAF2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TRAF2 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
5000.00 2.190 2.109
2500.00 1.494 1.413
1250.00 1.135 1.054
625.00 0.902 0.821
312.50 0.533 0.452
156.25 0.392 0.311
78.13 0.218 0.137
0.00 0.081 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant TRAF2 and the recovery rates were calculated by comparing the measured value to the expected amount of TRAF2 in samples.
Matrix Recovery range Average
serum(n=5) 95-108% 102%
EDTA plasma(n=5) 88-100% 94%
Heparin plasma(n=5) 81-113% 97%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TRAF2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-97% 82-120% 90-119% 82-90%
EDTA plasma(n=5) 82-112% 88-107% 84-115% 88-93%
Heparin plasma(n=5) 92-98% 90-112% 89-99% 87-97%

产品成分表

关闭

在线咨询

Online consultation

  • 在线咨询
  • 技术支持

关注微信公众号

微信扫一扫立即咨询

微信扫一扫立即咨询

关闭
Baidu
sogou