99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

人肺表面活性蛋白D(SP-D)微量上样酶联免疫吸附检测试剂盒
一键复制产品信息
ELK8561MS
规格: 价格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human SP-D(Pulmonary surfactant-associated protein D) Microsample ELISA Kit
Reactivity: Human
Alternative Names: SFTPD; SPD; SFTP 4;
Assay Type: Sandwich
Sensitivity: 0.51 ng/mL
Standard: 80 ng/mL
Detection Range: 1.25-80 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, lung lavage fluid, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Infection immunity;Pulmonology;
Uniprot ID: P35247
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human SP-D. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human SP-D. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human SP-D, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human SP-D in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
80.00 2.206 2.100
40.00 1.717 1.611
20.00 1.069 0.963
10.00 0.907 0.801
5.00 0.588 0.482
2.50 0.324 0.218
1.25 0.227 0.121
0.00 0.106 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant SP-D and the recovery rates were calculated by comparing the measured value to the expected amount of SP-D in samples.
Matrix Recovery range Average
serum(n=5) 81-104% 93%
EDTA plasma(n=5) 90-107% 99%
Heparin plasma(n=5) 94-119% 107%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SP-D and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-115% 84-113% 89-118% 94-103%
EDTA plasma(n=5) 81-112% 89-104% 89-97% 85-112%
Heparin plasma(n=5) 81-103% 82-110% 82-99% 84-113%