Overview

Product name: Human CK-18(Cytokeratin 18) Microsample ELISA Kit
Reactivity: Human
Alternative Names: Cell proliferation inducing gene 46 protein ; Cell proliferation inducing protein 46 ; Cell proliferation-inducing gene 46 protein ; CK 18 ; CK-18 ; CK18 ; CYK 18 ; CYK18 ; Cytokeratin 18 ; Cytokeratin endo B ; Cytokeratin-18 ; K 18 ; K18 ; K1C18_HUMAN ; KA18 ; Keratin 18 ; Keratin 18, type I ; Keratin D ; keratin, type I cytoskeletal 18 ; Keratin-18 ; Krt18
Assay Type: Sandwich
Sensitivity: 0.054 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Cancer of the liver; Viral hepatitis
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CK-18. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CK-18. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CK-18, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CK-18 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
10.00 1.895 1.800
5.00 1.668 1.573
2.50 1.031 0.936
1.25 0.815 0.720
0.63 0.509 0.414
0.31 0.322 0.227
0.16 0.191 0.096
0.00 0.095 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CK-18 and the recovery rates were calculated by comparing the measured value to the expected amount of CK-18 in samples.
Matrix Recovery range Average
serum(n=5) 91-101% 96%
EDTA plasma(n=5) 82-104% 93%
Heparin plasma(n=5) 94-115% 105%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CK-18 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 93-107% 90-113% 83-89% 92-113%
EDTA plasma(n=5) 93-106% 83-99% 81-111% 81-88%
Heparin plasma(n=5) 81-92% 95-109% 85-103% 92-105%