人白细胞抗原DR(HLADR)微量上样酶联免疫吸附检测试剂盒
一键复制产品信息
ELK8747MS
规格: 价格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human HLA-DR(Leukocyte Antigen DR) Microsample ELISA Kit
Reactivity: Human
Alternative Names: HALDR; Human leukocyte antigen DR
Assay Type: Sandwich
Sensitivity: 12.5 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Immune molecule
Uniprot ID: P01903
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human HLA-DR. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human HLA-DR. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human HLA-DR, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human HLA-DR in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
2000.00 2.105 2.014
1000.00 1.653 1.562
500.00 1.186 1.095
250.00 0.784 0.693
125.00 0.551 0.460
62.50 0.347 0.256
31.25 0.224 0.133
0.00 0.091 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant HLA-DR and the recovery rates were calculated by comparing the measured value to the expected amount of HLA-DR in samples.
Matrix Recovery range Average
serum(n=5) 81-107% 94%
EDTA plasma(n=5) 80-103% 92%
Heparin plasma(n=5) 93-100% 97%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HLA-DR and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 81-120% 91-119% 81-103% 92-107%
EDTA plasma(n=5) 85-113% 93-108% 83-92% 94-109%
Heparin plasma(n=5) 82-96% 83-113% 91-112% 84-106%