99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

人可溶性白介素33(sIL33)微量上样酶联免疫吸附检测试剂盒
一键复制产品信息
ELK9350MS
规格: 价格:
48T ¥2240.00
96T ¥3200.00

Overview

Product name: Human sIL33(Soluble Interleukin 33) Microsample ELISA Kit
Reactivity: Human
Alternative Names: IL-33;DV27; C9ORF26; IL1F11; NFHEV; Interleukin-1 Family, Member 11; Nuclear factor from high endothelial venules
Assay Type: Sandwich
Sensitivity: 3 pg/mL
Standard: 500 pg/mL
Detection Range: 7.82-500 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Infection immunity;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human sIL33. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human sIL33. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human sIL33, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human sIL33 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
500.00 2.094 2.000
250.00 1.543 1.449
125.00 1.240 1.146
62.50 0.892 0.798
31.25 0.582 0.488
15.63 0.328 0.234
7.81 0.231 0.137
0.00 0.094 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant sIL33 and the recovery rates were calculated by comparing the measured value to the expected amount of sIL33 in samples.
Matrix Recovery range Average
serum(n=5) 81-101% 91%
EDTA plasma(n=5) 89-103% 96%
Heparin plasma(n=5) 83-113% 98%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of sIL33 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 84-100% 94-112% 83-115% 87-97%
EDTA plasma(n=5) 90-114% 84-115% 92-108% 94-105%
Heparin plasma(n=5) 86-95% 86-116% 88-112% 91-99%

产品成分表

关闭

在线咨询

Online consultation

  • 在线咨询
  • 技术支持

关注微信公众号

微信扫一扫立即咨询

微信扫一扫立即咨询

关闭
Baidu
sogou