99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

人少突胶质细胞系转录因子2(OLIG2)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK9367
规格: 价格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human OLIG2(Oligodendrocyte Lineage Transcription Factor 2) ELISA Kit
Reactivity: Human
Alternative Names: BHLHB1; OLIGO2; PRKCBP2; RACK17; Basic Domain,Helix-Loop-Helix Protein,Class B 1; Class B basic helix-loop-helix protein 1; Class E basic helix-loop-helix protein 19
Assay Type: Sandwich
Sensitivity: 5.5 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample type: Tissue homogenates, cell lysates and other biological fluids.
Assay length: 3.5h
Research Area: Neuro science;
Uniprot ID: Q13516
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human OLIG2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human OLIG2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human OLIG2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human OLIG2 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
1000.00 2.054 1.968
500.00 1.593 1.507
250.00 1.282 1.196
125.00 0.828 0.742
62.50 0.595 0.509
31.25 0.366 0.280
15.63 0.249 0.163
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant OLIG2 and the recovery rates were calculated by comparing the measured value to the expected amount of OLIG2 in samples.
Matrix Recovery range Average
serum(n=5) 85-97% 91%
EDTA plasma(n=5) 84-97% 90%
Heparin plasma(n=5) 80-95% 87%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of OLIG2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 79-92% 86-97% 88-95% 89-99%
EDTA plasma(n=5) 83-99% 78-92% 83-96% 87-98%
Heparin plasma(n=5) 95-102% 86-97% 91-105% 93-103%