人前心钠肽(Pro-ANP)微量上样酶联免疫吸附检测试剂盒
一键复制产品信息
ELK9496MS
规格: 价格:
48T ¥2240.00
96T ¥3200.00

Overview

Product name: Human Pro-ANP(Pro Atrial Natriuretic Peptide) Microsample ELISA Kit
Reactivity: Human
Alternative Names: NT-proANP; Pro Atrial Natriuretic Peptide
Assay Type: Sandwich
Sensitivity: 0.057 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Endocrinology;Cardiovascular biology
Uniprot ID: P01160
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human Pro-ANP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human Pro-ANP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human Pro-ANP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human Pro-ANP in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
10.00 2.193 2.096
5.00 1.531 1.434
2.50 1.264 1.167
1.25 0.900 0.803
0.63 0.535 0.438
0.31 0.310 0.213
0.16 0.234 0.137
0.00 0.097 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant Pro-ANP and the recovery rates were calculated by comparing the measured value to the expected amount of Pro-ANP in samples.
Matrix Recovery range Average
serum(n=5) 87-102% 95%
EDTA plasma(n=5) 86-95% 91%
Heparin plasma(n=5) 82-117% 100%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Pro-ANP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 93-114% 93-108% 83-115% 92-118%
EDTA plasma(n=5) 85-100% 93-109% 91-116% 89-95%
Heparin plasma(n=5) 85-105% 90-117% 93-119% 95-114%