Overview

Product name: Human SMOC1(SPARC related modular calcium binding 1) ELISA Kit
Reactivity: Human
Alternative Names: Secreted modular calcium-binding protein 1
Assay Type: Sandwich
Sensitivity: 22.5 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample type: Serum, plasma, tissue homogenates
Assay length: 3.5h
Research Area: eye and limb development
Uniprot ID: Q9H4F8
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human SMOC1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human SMOC1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human SMOC1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human SMOC1 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
5000.00 2.035 1.947
2500.00 1.527 1.439
1250.00 1.128 1.040
625.00 0.821 0.733
312.50 0.547 0.459
156.25 0.336 0.248
78.13 0.230 0.142
0.00 0.088 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant SMOC1 and the recovery rates were calculated by comparing the measured value to the expected amount of SMOC1 in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 87-97% 90%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SMOC1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-101% 87-96% 93-108% 80-101%
EDTA plasma(n=5) 87-96% 88-96% 81-95% 95-105%
Heparin plasma(n=5) 88-102% 82-92% 86-94% 81-95%