99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

小鼠血管粘附蛋白1(VAP-1)微量上样酶联免疫吸附检测试剂盒
一键复制产品信息
ELK9608MS
规格: 价格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Mouse VAP-1(VascularAdhesion Protein 1) Microsample ELISA Kit
Reactivity: Mouse
Alternative Names: AOC3 ; HPAO; SSAO; Amine oxidase; copper containing 3
Assay Type: Sandwich
Sensitivity: 0.1 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Immunology;Signal Transduction
Uniprot ID: O70423
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse VAP-1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse VAP-1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse VAP-1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse VAP-1 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
10.00 1.961 1.872
5.00 1.590 1.501
2.50 1.261 1.172
1.25 0.884 0.795
0.63 0.538 0.449
0.31 0.351 0.262
0.16 0.216 0.127
0.00 0.089 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant VAP-1 and the recovery rates were calculated by comparing the measured value to the expected amount of VAP-1 in samples.
Matrix Recovery range Average
serum(n=5) 83-90% 87%
EDTA plasma(n=5) 84-121% 103%
Heparin plasma(n=5) 91-111% 101%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of VAP-1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-107% 86-104% 84-93% 89-108%
EDTA plasma(n=5) 84-119% 81-109% 81-97% 91-106%
Heparin plasma(n=5) 86-108% 82-118% 85-93% 84-97%

产品成分表

关闭

在线咨询

Online consultation

  • 在线咨询
  • 技术支持

关注微信公众号

微信扫一扫立即咨询

微信扫一扫立即咨询

关闭
Baidu
sogou