99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

兔固醇调节元件结合转录因子1(SREBP1)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK9798
规格: 价格:
48T ¥2240.00
96T ¥3200.00

Overview 文献(1)

Product name: Rabbit SREBP1(Sterol regulatory element-binding protein 1) ELISA Kit
Reactivity: Rabbit
Alternative Names: SREBF1; BHLHD1; SREBP1; Sterol regulatory element-binding protein 1; SREBP-1; Class D basic helix-loop-helix protein 1; bHLHd1; Sterol regulatory element-binding transcription factor 1
Assay Type: Sandwich
Sensitivity: 0.059 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample type: Tissue homogenates, cell lysates and other biological fluids
Assay length: 3.5h
Research Area: Cardiovascular; Epigenetics and Nuclear Signaling; Cancer; Metabolism
Uniprot ID: Q9MYY5
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rabbit SREBP1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rabbit SREBP1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rabbit SREBP1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rabbit SREBP1 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
10.00 2.036 1.940
5.00 1.515 1.419
2.50 1.043 0.947
1.25 0.871 0.775
0.63 0.556 0.460
0.32 0.335 0.239
0.16 0.215 0.119
0.00 0.096 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant SREBP1 and the recovery rates were calculated by comparing the measured value to the expected amount of SREBP1 in samples.
Matrix Recovery range Average
serum(n=5) 96-107% 102%
EDTA plasma(n=5) 82-98% 87%
Heparin plasma(n=5) 89-107% 98%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SREBP1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-104% 93-105% 87-103% 81-93%
EDTA plasma(n=5) 89-104% 78-96% 89-96% 79-98%
Heparin plasma(n=5) 82-91% 86-93% 81-94% 85-92%