99499威尼斯(中国·WWW认证)游戏内容-Macau App Station

产品中心

人胱天蛋白酶2(CASP2)酶联免疫吸附检测试剂盒
一键复制产品信息
ELK9940
规格: 价格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human CASP2(Caspase 2) ELISA Kit
Reactivity: Human
Alternative Names: CPP32; CPP32B; SCA1; Apoptain; Yama; Apoptosis-Related Cysteine Peptidase; Cysteinyl Aspartate Specific Proteinases 3; SREBP cleavage activity 1
Assay Type: Sandwich
Sensitivity: 26.52 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample type: tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay length: 3.5h
Research Area: Signal transduction;Enzyme & Kinase;Apoptosis;Tumor immunity;Infection immunity;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CASP2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CASP2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CASP2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CASP2 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
5000.00 2.079 1.991
2500.00 1.624 1.536
1250.00 1.032 0.944
625.00 0.837 0.749
312.50 0.532 0.444
156.25 0.357 0.269
78.13 0.124 0.036
0.00 0.088 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CASP2 and the recovery rates were calculated by comparing the measured value to the expected amount of CASP2 in samples.
Matrix Recovery range Average
serum(n=5) 86-94% 90%
EDTA plasma(n=5) 81-93% 87%
Heparin plasma(n=5) 83-101% 87%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CASP2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 79-97% 90-99% 95-103% 89-97%
EDTA plasma(n=5) 85-101% 93-104% 87-103% 91-102%
Heparin plasma(n=5) 79-95% 96-105% 85-96% 90-99%